OEM/ODM Supplier Dsc Cardiac Troponin I (Ctni) Test Kit - Infusion pump BYS-820 series – DSC
OEM/ODM Supplier Dsc Cardiac Troponin I (Ctni) Test Kit - Infusion pump BYS-820 series – DSC Detail:
Features of Infusion Pump
1. HD LCD Display, high capacity words, friendly user interface, dynamically display working status;
2. Audible and visual alarm for occlusion, empty, low battery, end of infusion, door open, wrong setting, etc., which gain patents;
3. Compatible with any brands of infusion sets after correct calibration;
4. Preset solution volume to greatly reduce the workload of nurses;
5. Work mode: ml/h and drop/min can switch freely;
6. Three levels of occlusion: high, middle and low;
7. Purge function;
8. KVO (keep-vein-open) automatically opens as infusion is completed, KVO rate is 1-5ml/h(1ml/h step);
9. Power Source: AC100—240V, 50/60Hz; Internal Battery;
10. Automatically record the settings of last infusion;
11. OEM is available.
Specification of Infusion Pump
ate | 1ml/h ~ 1,200ml/h |
Flow Rate Accuracy | Within ±5% (after correct calibration) |
Mechanical precision | Within ±2% |
Purge Rate | 100ml/h ~ 1,000ml/h (100 ml/h step) |
Infusion Volume | 1ml ~ 9999ml |
Total Infusion Volume | 0.1ml ~ 9999.9ml |
KVO rate | 1ml/h ~ 5 ml/h (1ml/h step) |
Occlusion | High: 800mmHg ±200mmHg (106.7kPa±26.7kPa
Medium: 500mmHg ±100mmHg(66.7kPa±13.3kPa Low: 300mmHg ±100mmHg (40.7kPa±13.3kPa ) |
Unique audible and visible alarm | Human voice alarm for End of injection, occlusion, door open, bubbles in the tube, wrong setting, low battery, AC power pulled out etc. |
Power Source | AC 100V ~ 240V, 50/60Hz; Internal rechargeable Li battery, capacity≥1,600mAh, 4 hours internal battery backup |
Bubble detector | Ultrasonic wave detector; detection sensitivity ≥25μL |
Fuse | F1AL/250V, 2 pc inside |
Power Consumption | 18VA |
Operating Condition | Ambient temperature: +5℃ ~ +40℃;
Relative humidity: 20 ~ 90% Atmospheric pressure: 86.0kpa ~ 106.0kpa |
Transport & Storage Condition | Ambient temperature:-30℃ ~ +55℃
Relative humidity: ≤95% |
Equipment Classification | Class II, internal power supply, Type CF |
IP Classification | IPX4 |
Dimension | 140mm (L) ×157mm(W) ×220mm(H) |
Weight | 1.8kg (net weight) |
Details
1、Support ml/h and d/min mode nad can change by one key
2.German import silent motor IC and Japan motor,low noise, low vibration
3.Start with self checking function makes stably system running
Product detail pictures:
Related Product Guide:
We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our administration ideal for OEM/ODM Supplier Dsc Cardiac Troponin I (Ctni) Test Kit - Infusion pump BYS-820 series – DSC , The product will supply to all over the world, such as: America, Bangladesh, Italy, With the advanced workshop, professional design team and strict quality control system, based on mid- to high-end marked as our marketing positioning, our products are fast selling onto European and American markets with our own brands such as below Deniya, Qingsiya and Yisilanya.